Dimmers
Reporting Endpoint Status
The HTTP integration of dimmers and other similar devices (speed controllers, etc.) uses the following structure:
POST /services/gear/DeviceIntegrationService.svc/UpdateDimmerStatus HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"isOn": true,
"dimValue": 75,
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier or combination of device address and endpoint address in format [deviceAddress]:endpointAddress (e.g.: [device-1234]:1). These values can be found on the endpoint management page. | numeric |
| isOn | Indica si el artefacto está encendido (true) o apagado (false) | bool |
| dimValue | Indica el nivel de dimerización, como porcentaje entre 1 y 100. | numeric |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |
Reporting Status in "raw" Format
El estado del endpoint can be reported as a raw value using the expression converter. This option is convenient when the device is unable to perform conversions and emits values that need to be transformed before being injected into the platform.
Below is an example of a raw format request:
POST /services/gear/DeviceIntegrationService.svc/UpdateDimmerStatusRaw HTTP/1.1
Host: gear.cloud.studio
Content-Type: application/json
{
"accessToken": "xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx",
"endpointID": 1,
"rawData": "true/75",
"timestamp": "2021-02-23T14:55:03"
}Parameters
| Name | Description | Data Type |
|---|---|---|
| accessToken | Access token with permissions to update endpoint information. See this page for more information. | text |
| endpointID | Unique endpoint identifier, which can be found on the endpoint management page. | numeric |
| rawData | Valor reportado por el sensor, como texto. Deben indicarse dos expresiones en el conversor de expresiones:La primera expresión debe devolver un valor booleano indicando si el artefacto está encendido (true) o apagado (false).La segunda expresión debe devolver un valor numérico indicando el nivel de dimerización del aparato, como porcentaje entre 1 y 100. | text |
| timestamp | Optional value indicating the UTC date and time corresponding to the measurement. The date format must match one of those specified in the date formats section. If the field is omitted, the platform will assume the measurement corresponds to the current date and time. | text |